Fire safety
(135)
Fire safety on BUILDING SERVICES. Helping you find the best solution for your project.
Fire safety - helping you find the best solution for your project.
AlarmSense heat detector
Visit siteAlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The AlarmSense heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the two thermistorsSeries 65 A1R heat detector
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The A1R heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature, the other is sealed. In normal conditions, the twoSeries 65 12V relay base
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 12V relay base is designed for use in both fire and security systems. For fire systems, a jumper on the PCB is fitted to a latching position. For security systems the jumper is- PRODUCT
- Apollo Fire Detectors
Series 65 standard relay base
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard relay base provides one set of volt-free changeover (from C) contacts that change state when the detector signals an alarm. Features: Advanced electronic technology- PRODUCT
- Apollo Fire Detectors
XP95 multisensor detector
Visit site- XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander optical smoke detector works
Series 65 optical smoke detector
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered andConventional sounders and strobes range
Visit siteConventional sounders and sounder/strobes are suitable for both fire and security applications and are available in 4 and 14 tone versions. Low-profile, surface and waterproof versions are available, enabling the units to be used internally or externally. Detector base sounders and strobes are also available for use underneath smoke detectors or- PRODUCT
- KAC Alarm Company
Intelligent audible visual alarms
Visit siteKACs analogue addressable range of audible visual alarms has been designed to meet the requirements of modern intelligent fire systems. The alarms can be installed as traditional wall-mounted devices or as detector base devices. A separate, common installation base is installed to allow simple twist fit of the AV device. This has a shorting spring- PRODUCT
- KAC Alarm Company
AlarmSense optical smoke detector
Visit siteAlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by theExplosion suppression systems
Visit siteFM and ATEX approved chemical suppression systems operate within milliseconds to suppress an explosion before any damage is caused to plant or personnel are harmed. They are designed for process industry applications involving flammable dusts or powders, and in which there is potential for expensive or hazardous explosions in cyclones, filters- PRODUCT
- Fike United Kingdom
Interfaces input/output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The input/output unit provides a voltage-free, single-pole, change-over relay output, a single monitored switch input and an unmonitored- PRODUCT
- Apollo Fire Detectors
Interfaces sounder control unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The sounder control unit is used to control the operation of a zone of conventional sounders and report their status to the control panel. The unitInterfaces DIN-Rail zone monitor
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-Rail Zone Monitor with Isolator controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery orInterfaces DIN-Rail input/output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The DIN-rail output unit provides a voltage-free single-pole, change-over relay output. It is a simplified version of the input/output unit withoutXP95 optical smoke detector
Visit siteThe XP95 optical detector uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by the photo-diode. A signal is generated and transmitted digitally to the control equipment- PRODUCT
- Apollo Fire Detectors
Series 65 standard mounting base
Visit siteThe Series 65 range of conventional detectors incorporates well-proven sensing technologies, together with advances in materials and electronics technology. The Series 65 standard mounting base has been designed to enable detectors to be fitted without the need of force. It is particularly useful when fitting to suspended ceilings. All Series 65- PRODUCT
- Apollo Fire Detectors
XP95 ionisation smoke detector
Visit siteThe XP95 ionisation smoke detector uses irradiated air in the dual sensing chambers to produce ions that travel to the positive and negative electrodes, creating a current flow. As smoke enters the outer chamber, the flow drops and voltage increases. The voltage is measured and an analogue signal is converted to digital for transmission to the- AlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. The integrating optical smoke detector uses an internal pulsing LED and a photodiode at an obtuse angle. In the event of smoke entering the chamber, the light pulse from the LED will be scattered and registered by
AlarmSense sounder beacon base
Visit siteAlarmSense is a range of conventional detection and alarm products specially designed to be connected to the same pair of supply wires. Providing an alarm between 70 and 87dB(A), the AlarmSense sounder beacon base will detect the removal of a detector head and report a fault. It continues to work during unauthorised removal of detectors. Quick and- PRODUCT
- Apollo Fire Detectors
Discovery multisensor detector
Visit site- XPander is a wireless intelligent detector range in which individual alarm devices communicate with the XP95 loop by radio signals. Every device is assigned an address and this address is recognised by the control panel in the same way as is the address of any device connected directly to the loop wiring. The XPander multisensor detector contains
XP95 heat detector
Visit siteThe XP95 heat detector has a low air-flow resistant case for good contact between the sensing thermistor and the surrounding air. Temperature is measured by a single thermistor network which gives a voltage output proportional to the external air temperature. The signal is processed and transmitted to the control equipmentInterfaces three-channel input/output unit
Visit siteApollo manufactures Interfaces, a comprehensive range of intelligent systems. They enable fire protection systems to be engineered simply and effectively without the need for custom-designed equipment. The three-channel input/output unit provides three voltage-free, single pole, changeover relay outputs and three monitored switch inputs. The unit

Sign up to receive the free BUILDING SERVICES bulletin